Fat poured down a kitchen sink is liquid. Ten metres down the line it is a solid plug. A grease separator stops it before it sets.
Which one fits
- Under the sink or beside it: ACO Grease Trap (GT40 – GT120) and the automatic Grease Capture (GC50 – GC220).
- Food trucks and small pantries: LipuMobil-P.
- Hotel, hospital and food plant kitchens, in a plant room: LipuJet-P-O (NS 1 – 10), LipuJet-P-R and the special shape OAP (up to NS 60), or Lipator for partial disposal.
- Outside, in the ground: LipuMax-P (NS 2 – 10).
Separators are sized to EN 1825 from the fittings and the meals served. Send us the kitchen layout and we propose the nominal size (NS).

ACO Grease Trap
Model GT40, GT80, GT120
Stainless steel grease trap for restaurant and hotel kitchens, 2" inlet and outlet, with silt basket and flow reducer. GT40, GT80 and GT120.

ACO Grease Capture
Model GC50, GC100, GC150, GC220
Automatic stainless steel grease removal unit for kitchens, 0.5 to 2.2 l/s, that skims grease into a collection box. 230 V.

ACO LipuJet-P-OB
Model Basic type, NS 1 – 10 · DIN EN 1825, DIN 4040-100
Free-standing oval polyethylene grease separator, basic type, NS 1 to NS 10, to DIN EN 1825, for frost-free rooms in kitchens and food plants.

ACO LipuJet-P-OD
Model Extension stage 1, NS 1 – 10 · DIN EN 1825, DIN 4040-100
Free-standing oval polyethylene grease separator, extension stage 1, NS 1 to NS 10, to DIN EN 1825, for frost-free rooms in kitchens and food plants.

ACO LipuJet-P-OM
Model Extension stage 2, NS 1 – 10 · DIN EN 1825, DIN 4040-100
Free-standing oval polyethylene grease separator, extension stage 2, NS 1 to NS 10, to DIN EN 1825, for frost-free rooms in kitchens and food plants.

ACO LipuJet-P-OA
Model Extension stage 3, NS 1 – 10 · DIN EN 1825, DIN 4040-100
Free-standing oval polyethylene grease separator, extension stage 3, NS 1 to NS 10, to DIN EN 1825, for frost-free rooms in kitchens and food plants.

ACO LipuJet-P-OAP
Model Extension stage 3 with disposal pump, NS 1 – 10 · DIN EN 1825, DIN 4040-100
Free-standing oval polyethylene grease separator, extension stage 3 with disposal pump, NS 1 to NS 10, to DIN EN 1825, for frost-free rooms in kitchens and food plants.

ACO LipuJet-P-RB
Model Basic type, NS 15 – 22.5 · EN 1825
Large free-standing grease separator in round polyethylene segments, basic type, to EN 1825, for big kitchens and food plants.

ACO LipuJet-P-RD
Model Extension stage 1, NS 15 – 22.5 · EN 1825
Large free-standing grease separator in round polyethylene segments, extension stage 1, to EN 1825, for big kitchens and food plants.

ACO LipuJet-P-RM
Model Extension stage 2, NS 15 – 22.5 · EN 1825
Large free-standing grease separator in round polyethylene segments, extension stage 2, to EN 1825, for big kitchens and food plants.

ACO LipuJet-P-RA
Model Extension stage 3, NS 15 – 22.5 · EN 1825
Large free-standing grease separator in round polyethylene segments, extension stage 3, to EN 1825, for big kitchens and food plants.

ACO LipuJet-P-RAP
Model Extension stage 3 with disposal pump, NS 15 – 22.5 · EN 1825
Large free-standing grease separator in round polyethylene segments, extension stage 3 with disposal pump, to EN 1825, for big kitchens and food plants.

ACO LipuJet-P-OAP special shape
Model NS 15 – NS 30 · EN 1825
Large oval polyethylene grease separator, NS 15 to NS 30, with automatic high-pressure cleaning and a disposal pump, to EN 1825.

ACO LipuJet-P-OAP parallel
Model NS 40 – NS 60 · EN 1825
Two LipuJet-P-OAP separators installed in parallel with a distribution unit, NS 40 to NS 60, to EN 1825.

ACO Lipator-P-RM
Model NS 4 – NS 25 · EN 1825
Partial-disposal grease separator in welded polyethylene, NS 4 to NS 25: grease and sludge drawn off by hand through ball valves.

ACO LipuMax-P-B
Model Basic model, NS 2 – NS 10 · DIN EN 1825, DIN 4040-100
Underground polyethylene grease separator, basic model, NS 2 to NS 10, to DIN EN 1825, for restaurants and food sites with no plant room.

ACO LipuMax-P-D
Model Extension stage 1, NS 2 – NS 10 · DIN EN 1825, DIN 4040-100
Underground polyethylene grease separator, extension stage 1, NS 2 to NS 10, to DIN EN 1825, for restaurants and food sites with no plant room.

ACO LipuMobil-P
Model Type 0.3, Type 0.8
Small free-standing grease separator for food trucks, mobile dishwashers and occasional cooking, DN 50, up to 0.8 l/s.
Grease separators: questions
What is a grease trap and why does a commercial kitchen need one?
A grease trap holds kitchen wastewater long enough for fats and oils to float and food solids to settle, so they are kept out of the drain. Without one, grease cools and blocks the pipes and the sewer.
What size grease trap do I need?
It depends on the flow from the sinks, dishwashers and other fittings connected. A single sink line suits an under-sink trap such as the ACO GT40; a hotel or food plant needs a separator sized to EN 1825 in nominal sizes (NS). Send us the fitting list and we size it.
What is the difference between a grease trap and a grease separator?
A grease trap is a small unit for one sink or a small kitchen. A grease separator is a larger tank, sized to EN 1825, with a sludge trap and grease store, for a whole kitchen or food plant.
How often should a grease separator be emptied?
When the grease layer and sludge reach the levels in the maker's instructions, and at the intervals your local authority sets. Automatic ACO units such as the LipuJet-P-OA clean themselves between emptyings.
A size or rating not listed?
Our procurement desk sources it, from Valvetech or anywhere in the world.